Signals from NAMUR and SN sensors including line fault detection and short-circuit detection, as well as the measurement data from the two-wire DC sensors may be processed in accordance with EN 60947-5-2. Signals can be transferred safely in the control level from S0 sensors for measuring the water volume and from three-wire sensors with PNP or NPN switching outputs. With its S0 interface the rotation speed monitor is also of interest for areas outside industrial automation, such as building automation. The module can safely detect any signal up to 30V with an input frequency up to 50kHz. The device is set using a DIP switch or PC software. A start-up override is available to restart the system when standstill monitoring.
The SC-System includes a portfolio of signal conditioners for non-hazardous areas. With its space-saving enclosure design that is 6mm wide and 97mm high the modules are among the most compact on the market. They can be used at ambient temperatures of up to 70°C. The signal isolators are characterised by three-way isolation withstanding a working voltage up to 300V and a test voltage up to 3KV. Optionally, they are supplied by terminals or a power bus.